YIGU Sensors
Professional Weather Sensor & Weather Station Manufacturer
YGC-GHFS  PAR Sensor-01.jpg
YGC-GHFS  PAR Sensor-02.jpg
YGC-GHFS  PAR Sensor-03.jpg
YGC-GHFS  PAR Sensor-04.jpg
YGC-GHFS  PAR Sensor-05.jpg
YGC-GHFS Photosynthetically Active Radiation Sensor ( PAR Sensor)
【Payment】T/T, L/C or Paypal
【OEM/ODM】 Available
【MOQ】1 PCS
【Model】YGC-GHFS
【Lead Time】5-7 days
【Certification】CE, RoHS, ISO9001
 
WhatsApp: +86 15271247832
Description

YGC-GHFS Photosynthetically Active Radiation Sensor (PAR Sensor)

Product Introduction


YGC-GHFS Photosynthetically Active Radiation Sensor (PRA Sensor) is a device used to measure the radiation energy within a specific band (wavelengths of 400nm - 700nm) of the solar radiation spectrum that can be absorbed and converted by plant pigments for organic matter synthesis. The instrument is designed in strict accordance with the GB/T 35139-2017 national standard. It consists of sensing components, optical filters, a cosine corrector, a signal output terminal, and structural components.

 

The PAR Sensor adopts an aluminum alloy housing, featuring a robust structure, excellent sealing, long service life, high measurement accuracy, good stability, long transmission distance, and strong resistance to external interference. It is widely applicable in environments such as agriculture, aquaculture, greenhouses, laboratories, and any scenario requiring photosynthetically active radiation measurement.

YGC-GHFS  PAR Sensor Advantages.jpg

 

Technical Parameters


Parameter Specification
Spectral Range 400 ~ 700 nm
Measurement Range (Energy) ☐ 0 ~ 1500 W/m² (Default)
Measurement Range (Quantum) ☐ 0 ~ 5000 μmol·m⁻²·s⁻¹
Resolution 1 W/m² (or 1 μmol·m⁻²·s⁻¹)
Response Time ≤ 5 ms (95%)
Nonlinearity ± 4%
Directional Response ± 10% (corrected within zenith angle ≤ 80°)
Temperature Response ± 5% (-20°C ~ 60°C)
Annual Stability ± 3%
Spectral Response Bandwidth 400 ± 10 nm ~ 700 ± 10 nm
Spectral Selectivity Error ± 5%
Response Outside Bandwidth ≤ 10%
Power Supply ☐ DC 5V    ☐ DC 9~30V
Output Signal (Current) ☐ 4 ~ 20 mA
Output Signal (Voltage) ☐ 0 ~ 5 V
Output Signal (Serial Port) ☐ RS485 (Modbus / ASCII)
☐ RS232 (Modbus / ASCII)
Cable Length ☐ Standard: 2m
* Custom lengths available upon request
Power Consumption ≤ 100 mW @ 5V
Protection Level IP67
Operating Temperature -40°C ~ 80°C
Relative Humidity 0 ~ 100% RH

Note: ☐ indicates an optional item.

💡 Customization Available (OEM/ODM): We tailor Measurement range, power supply, output signals, and cable lengths to your specific project needs. Contact us for details.

 

Product Details


✅ All-Aluminum Enclosure for Long Lifespan

Delivers outstanding stability, high-temperature tolerance, and exceptional durability with anti-aging properties.

 

✅ IP67 High Protection Rating

The sensor features a rugged, corrosion-resistant housing with IP67 ingress protection, making it fully waterproof and dust-tight. Designed for long-term reliability, it operates stably even in harsh outdoor environments with heavy rain and snow.

YGC-GHFS  PAR Sensor-Details 01.jpg

✅ High Sensitivity for Accurate PAR Detection

Equipped with a photodetector highly sensitive to the 400–700 nm waveband, the sensor precisely measures the intensity of photosynthetically active radiation (PAR) with high accuracy.

YGC-GHFS  PAR Sensor-Details 02.jpg

 

Factory Calibration & Quality Control


✅ Strict Factory Calibration Process

To guarantee measurement accuracy, every PAR sensor is calibrated using equipment designed in accordance with GB/T 33865-2017 and other national standards. During the process, a factory-calibrated PAR meter is used as the reference standard for comparison. This rigorous calibration workflow ensures high precision and guarantees data consistency across all batch production units.

YGC-GHFS  PAR Sensor Calibration & Testing-01.jpg

✅ High-Low Temperature & Humidity Test Chamber

Provides a highly stable, controlled environment to ensure both reference standards and target products are calibrated under identical temperature and humidity conditions, eliminating environmental deviations.

YGC-GHFS  PAR Sensor Calibration & Testing-02.jpg

✅ Long-Term Outdoor Exposure Test

Sensors are mounted on weather stations for months of continuous monitoring to verify data stability, anti-aging performance, and long-term reliability under real-world weather conditions.

YGC-GHFS  PAR Sensor Calibration & Testing-03.jpg

Dimensions


YGC-GHFS  PAR Sensor Dimensions.jpg

Photosynthetically Active Radiation Basics


The five photosynthetic reactions of plants—photosynthesis, pigment synthesis, photoperiod phenomena, phototropism, and photomorphogenesis—all occur within the wavelength range of 400–700nm. Therefore, the radiation within the 400–700nm range is commonly referred to as Photosynthetically Active Radiation (PAR). PAR is represented by the symbol Qp, with units of W/m² or μmol·m⁻²·s⁻¹. It is the energy source for plant life activities, organic matter synthesis, and yield formation.

 

CONTACT US


📲 Tel/Whatsapp:+86 15271247832

📞 Tel:+86 19522958500

✉️ Email: info@whchenyun-tech.com

📍Address:Room 301, Building 4, Gezhouba Sun City Industrial Park, East Lake High-Tech Development Zone, Wuhan, Hubei Province, China

No Additional Information
Related products
Contact us

YIGU Sensors
Professional Weather Sensor & Weather Station Manufacturer

Telephone: +86-027-87915379

 WhatsApp:+86 15271247832(Liang)

 Email: info@whchenyun-tech.com

 Address: Room 301, Building 4, Gezhouba Sun City Industrial Park, East Lake High-Tech Development Zone, Wuhan, Hubei Province, China

Get In Touch
Address
Room 301, Building 4, Gezhouba Sun City Industrial Park, East Lake High-Tech Development Zone, Wuhan, Hubei Province, China
Phone
+86 19522958500
SUBSCRIBE NEWSLETTER
  • Get all the latest information on events, sales and offers. Sign up for newsletter:

WhatsApp

Scan or click to chat

WeChat

Scan to chat with us

Cloud Data

Scan to view cloud data

Copyrights © 2013-2026 Wuhan Chenyun Technology Co., Ltd. All rights reserved | Private Policy